C-TEC CFP Standard 8 zone panel
LPCB certified to EN54-2/4, C-TEC's CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.
- Requires 2 x 12V 3.2Ah VRLA batteries.
- Colour-coded buttons and combined keypad/keyswitch entry.
- Eight detector zone circuits.
- Four conventional sounder circuits
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- Installer-friendly design.
- Low 25mA quiescent current.
- Multiple indicators.
SKU | CTEC-CFP708-4 |
---|---|
Manufacturer Part Code | CFP708-4 |
Material | Plastic |
Ingress Protection | IP30 |
Depth (mm) | 96.00 mm |
Width (mm) | 380.00 mm |
Length (mm) | 235.00 mm |
c/w Batteries? | Yes |
Voltage | 230V |
Output Capacity | 3.2 A/Hr |
Number of Zones | 8 |
Maximum number of detectors | 25 |
Standards | EN54-2/4 |
Is on Sale | No |
Fire & Intruder Alarms | Description | Product | Fire Alarm Panel | |
Fire & Intruder Alarms | Description | Product Type | CFP Standard 8 Zone | |
Fire & Intruder Alarms | Description | Qualifier | Fire | |
Fire & Intruder Alarms | Dimensions | Depth (EF008810) | 96 mm | |
Fire & Intruder Alarms | Features | Ingress Protection (EF005474) | IP30 | |
Fire & Intruder Alarms | Features | Integral Charger | 350 mA | |
Fire & Intruder Alarms | Features | Maximum number of detectors | 25 | |
Fire & Intruder Alarms | Features | Number of Zones | 8 | |
Fire & Intruder Alarms | Features | Output Capacity | 3.2 A/Hr | |
Fire & Intruder Alarms | Features | Power Supply Mains | 230 V | |
Fire & Intruder Alarms | Features | c/w Batteries | Y | |
Fire & Intruder Alarms | Features | c/w Call Points | Y | |
Fire & Intruder Alarms | General | CE Approved | Y | |
Fire & Intruder Alarms | General | Standards | EN54-2/4 | |
Fire & Intruder Alarms | General | Unit Weight | 1.75 kg | |
Fire & Intruder Alarms | Technical Data | Current Rating (EF000227) | 1.5 A | |
Fire & Intruder Alarms | Technical Data | Maximum Operating Temperature | 40 Degrees C |